- Models VCRD3R, VCRD4R, VCRD5R
- Storage cupboard with fan-assisted refrigeration.
- Internal mid and base shelves are removable for easy cleaning.
- Hinged doors seal cupboard with magnetic gaskets.
Refrigerated Multi-Tier Display Unit with Ambient Shelf Under
- Models VCRD3, VCRD4, VCRD5
- Refrigerated multi tier display unit with chilled well, three glass adjustable shelves and ambient shelf under.
- Curtain of cold re-circulating air cascades down from top, ensuring even temperature of 2°C to 8°C.
Warning: These units are not designed to operate in full mode for more than 24 hours, unless an optional front blind has been fitted.
Features
- If the unit is to be used over a 24 hour period with the optional front blind, the blind should be pulled down as soon as possible after service has stopped.
- Stream of re-circulating cold air is blown up and across the display shelves and chilled well, ensuring temperature is maintained safely
- Glass display shelves are removable and have adjustable brackets.
- Chilled well has removable base sections for easy cleaning and maintenance.
- Automatic defrost cycle.
- Pull out condensate drip tray.
Model VCRW4
IMPORTANT: To obtain the maximum performance and efficiency from these units it is imperative that the ambient room conditions where the units are being used do not exceed a temperature off 25°C or exceed a relative room humidity of 50%.
WARNING: Should conditions exceed the above the display units will not maintain food temperatures at required levels Versigen cannot accept responsibility for the performance of the units being used in extreme conditions.
- Do not install units in draughty conditions where the air movement is greater than 0.2mtr./sec. (For example near entrance/ exit doors, open windows, under air conditioning vents or ceiling mounted fan).
- Do not install units where there is high solar radiated heat (for example, direct sunlight, room heaters or bright spotlights)
- When loading refrigerated display units for best performance and refrigeration efficiency a gap should be left between the products allowing the cold air to pass through and re-circulate.
Note: All refrigerated units are available with refrigerated storage cupboard. Add R to the standard code.
Note: Refrigerated units are designed for straight through ventilation. If units are to be placed against a wall. Please see our Versicarte Plus Wall Unit Displays.
- Models VCRW3R, VCRW4R, VCRW5R
- Storage cupboard with fan-assisted refrigeration.
- Internal mid and base shelves are removable for easy cleaning.
- Hinged doors seal cupboard with magnetic gaskets.
- Do not install units in draughty conditions where the air movement is greater than 0.2mtr./sec. (For example near entrance/ exit doors, open windows, under air conditioning vents or ceiling mounted fan).
- Do not install units where there is high solar radiated heat (for example, direct sunlight, room heaters or bright spotlights)
- When loading refrigerated display units for best performance and refrigeration efficiency a gap should be left between the products allowing the cold air to pass through and re-circulate.
IMPORTANT: To obtain the maximum performance and efficiency from these units it is imperative that the ambient room conditions where the units are being used do not exceed a temperature off 25°C or exceed a relative room humidity of 50%.
WARNING: Should conditions exceed the above the display units will not maintain food temperatures at required levels. Versigen cannot accept responsibility for the performance of the units being used in extreme conditions.
Refrigerated Well (Wall Unit) with Ambient Shelf Under. Well Models VCRW3FC, VCRW4FC, VCRW5FC
Model VCPW4, shown with optional standard triple tube drop down tray slide.
- Models VCPW2, VCPW3, VCPW4, VCPW5
- Polar well supplied with Versigen Polar Plates, ambient storage cupboard, optional illuminated gantry and interchangeable glass screen.
- Polar Plates keep food chilled for 2 to 3 hours. Before use, the Polar Plates are charged for 8 to 12 hours in a deep freeze.If longer periods of operation are required, extra Polar Plates can be charged and used in rotation.
- Storage cupboard sliding doors are removable for easy cleaning.
- All internal shelves are removable for cleaning.
- Optional illuminated gantry with on/off switch indicating power is on.
Polar Plates
Polar plates must firstly be charged for 12/24 hours in a deep freeze. They are then placed inside the well where they give off a steady flow of cold air for a minimum of two hours. Once used, other polar plates can then be substituted thus keeping the well cold.